From Fedora Project Wiki

(Created page with '{{QA/Test_Case |description=This case mainly tests the usability of storagefiltering. |actions= # Ideally, find a testbed with MANY LUNs. # Boot the installer using any available...')
 
No edit summary
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{QA/Test_Case
{{QA/Test_Case
|description=This case mainly tests the usability of storagefiltering.
|description=This case mainly tests the usability of {{package|anaconda}} [[Anaconda/Features/StorageFiltering|storage filtering]] and the improved [[Anaconda/Features/UICleanup|storage filtering user interface]].
|actions=
|actions=
# Ideally, find a testbed with MANY LUNs.
# Ideally, find a testbed with MANY LUNs.
Line 7: Line 7:
# Check the devices shown in the UI.
# Check the devices shown in the UI.
# Test all the normal functions in the test matrix, including searching and filtering.
# Test all the normal functions in the test matrix, including searching and filtering.
# Select and Don't select certain devices in the filtering UI.
# Select and deselect certain devices in the filtering UI.
|results=
|results=
# All the normal functions in the test matrix works.
# All the normal functions in the test matrix works.
Line 15: Line 15:
# On the cleardisks UI, aggregate devices (RAID, multipath) should appear as one thing, not as their component parts.
# On the cleardisks UI, aggregate devices (RAID, multipath) should appear as one thing, not as their component parts.
}}
}}
[[Category:Installer_Partitioning_Test_Cases]]

Latest revision as of 02:46, 22 April 2010

Description

This case mainly tests the usability of Package-x-generic-16.pnganaconda storage filtering and the improved storage filtering user interface.


How to test

  1. Ideally, find a testbed with MANY LUNs.
  2. Boot the installer using any available means
  3. At type of devices step, choose Specialized Storage Devices and click Next.
  4. Check the devices shown in the UI.
  5. Test all the normal functions in the test matrix, including searching and filtering.
  6. Select and deselect certain devices in the filtering UI.

Expected Results

  1. All the normal functions in the test matrix works.
  2. Certain devices not selected in the filtering UI do not show up in later storage UI.
  3. Added iscsi disks, zfcp, etc. show up automatically in the advanced filtering UI.
  4. On machines with advanced storage capabilities, verify those don't show up in the simple filtering UI.
  5. On the cleardisks UI, aggregate devices (RAID, multipath) should appear as one thing, not as their component parts.