From Fedora Project Wiki

Revision as of 19:03, 20 March 2011 by Jskarvad (talk | contribs)

Description

This test case tests the PowerTOP 2.x power estimation engine.

Note.png
This test targets laptop users.
Note.png
This test can take one hour or more, but most of this test can be run in background enabling the user to use her/his computer for other tasks.
Note.png
If you do not have laptop or if you do not have enough time feel free to skip this test. In this case please leave the corresponding column in the results table blank.

Setup

  1. Check that you have pm-test-day package installed:
    $ rpm -q pm-test-day

The calibration process could be affected by other power savings mechanisms. The PowerTOP can control brightness and wireless devices, thus we need to disable screensaver, screen dimming/turning off, transition to sleep mode, HDD power savings and cron service. Scripts are provided:

  1. Disable user PM via gconf (and save previous settings):
    $ pmtd-pm-user-settings saveoff
    • After the test it is possible to restore the previous settings by using the restore parameter instead of saveoff:
  2. Disable system PM (and save previous settings):
    # pmtd-pm-system-settings saveoff
    • After the test it is possible to restore the previous settings by using the restore parameter instead of saveoff:

How to test

Note.png
This test needs to be run on battery.
Warning.png
If your battery is charged to less than 50% of its capacity please re-charge it before this test.
  1. Disconnect AC and run on battery.
  2. Start calibration by:
    # powertop --calibrate
    • During the calibration process the PowerTOP will change various settings of your system including the LCD backlight, let it run. It will take approx. 10 minutes. Do not use your computer while calibrating. After the calibration the PowerTOP will start automatically.
  3. Let the PowerTOP run to collect enough data. You can let it run in the background and simultaneously work with your computer as usual. In active idle the collection process can take 1 hour or more. After enough data are collected, the PowerTOP will start showing the estimation of power consumption for each item.

Expected Results

  1. PowerTOP successfully collects calibration data.
  2. Power consumption estimation starts showing for each item in the first column.